Summary of DETECTOR-FILTER COMBINATION SERIES PLANAR DIFFUSED SILICON PHOTODIODES
OSI Optoelectronics offers a detector-filter combination series integrating filters with photodiodes for tailored spectral responses, available with NIST traceable calibration. The PIN-10DF provides flat responsivity for radiometric measurements with high sensitivity and stability compared to thermopiles. The PIN-10AP mimics the human eye's CIE curve within 4% accuracy. Additionally, the PIN-005D-254F features a UV-enhanced photodiode with a narrow bandpass filter peaking at 254 nm.
Parts used in the Detector-Filter Combination Series:
- PIN-10DF
- PIN-10AP
- PIN-005D-254F
OSI Optoelectronics’ detector-filter combination series incorporates a filter with a photodiode to achieve a tailored spectral response in a multitude of standard and custom combinations. All detector-filter combinations can be provided with a NIST traceable calibration data specified in terms of amps/watts, amps/lumen, amps/lux, or amps.
The PIN-10DF is a 1 cm2 active area, BNC package detector-filter combination optimized to achieve a flat responsivity from 450 nm to 950 nm. This is the spectral response required for radiometric measurements. This type of detector has several advantages over thermopile, such as sensitivity, which is about a thousand times higher, as well as 10 times more stability.
The PIN-10AP is a 1 cm2 active area, BNC package detector-filter combination which duplicates the response of the most commonly available optical aid, the human eye. The eye senses both brightness and color with response varying as a function of the wavelength. This response curve is commonly known as the CIE curve. The AP filters accurately match the CIE curve to within 4% of the area.
The PIN-005D-254F is a 6 mm2 active area, UV enhanced photodiode-filter combination which utilizes a narrow bandpass filter peaking at 254 nm.
Read more: DETECTOR-FILTER COMBINATION SERIES PLANAR DIFFUSED SILICON PHOTODIODES
- What is the purpose of the OSI Optoelectronics detector-filter combination series?
To achieve a tailored spectral response in standard and custom combinations. - Can these detectors be provided with NIST traceable calibration data?
Yes, all combinations can be provided with NIST traceable calibration data specified in amps/watts, amps/lumen, amps/lux, or amps. - How does the PIN-10DF differ from a thermopile?
The PIN-10DF has sensitivity about a thousand times higher and 10 times more stability than a thermopile. - What spectral range does the PIN-10DF cover?
It achieves a flat responsivity from 450 nm to 950 nm. - Which detector duplicates the response of the human eye?
The PIN-10AP duplicates the response of the human eye. - How accurately does the AP filter match the CIE curve?
The AP filters match the CIE curve to within 4% of the area. - What is the active area of the PIN-005D-254F?
The PIN-005D-254F has a 6 mm2 active area. - At what wavelength does the PIN-005D-254F peak?
It utilizes a narrow bandpass filter peaking at 254 nm.